How to Measure pH of Solidified Products

Asked by: akakkoii On: June 14, 2017 Product Type: Cosmetics

Question

How can I measure the pH of a finished product, such as a cream, that has solidified? Should I dilute it with Purified Water before measuring with a pH meter, and if so, what dilution ratio is appropriate for checking skin compatibility versus manufacturing quality control?

Answer

Measuring pH in Solidified Products

To measure the pH of a finished product that has solidified, you can do so by diluting the product in purified water to bring it into a liquid state suitable for measurement.

  • Dilution Method: Take the solidified product and mix it with Purified Water in a sufficient amount to dissolve or disperse the product until it becomes a liquid.
  • Dilution Ratio:
    • If you want to know the pH value for general skin compatibility, dilute until it becomes liquid, ensuring the amount of water does not exceed 10 times the amount of the cream/product.
    • If the measurement is for manufacturing quality control, a specific dilution protocol should be established and used consistently for every measurement. For example, you might define mixing 1 part product with 5 parts distilled water before measuring the pH with a pH meter.

This dilution process helps ensure that the pH meter can measure the value accurately.

Related Products Mentioned