Digital pH meter (temporary use)

  • Product Code: 204

Digital pH meter (temporary use)

฿590.00
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -

Product warranty 7 days

Digital pH Meter Resolution 0.1 pH measurement range 0.0-14.0

The machine is red or yellow, can not choose depending on the stock of the product.

 

*Please calibrate the unit before first use, one set of calibration comes with the machine, please see how to calibrate below*

 

Range : 0.0 - 14.0 pH

Resolution : 0.1 pH

Accuracy : +/- 0.1pH

Operation Temp. : 0 C - 50 C (32 F-122F)

Calibration: 1 point

Power Supply: 1.5V x 4

Battery Life : Approximately 600-800 hours

Size: 148mm x 28 x 15 mm

Weight : 60g

Made from: China

 

 

How to Calibrate the Machine (Please do it before the first use. for accurate measurements)

- Prepare 250ml of distilled water with a temperature of approx. 25 degrees or close

- Pour the Calibrate pH 6.86 powder (included in the box) into the water, stir until completely dissolved.

- In a pH meter dipped in the prepared solution. and check the resulting pH

- If the pH does not match 6.9, use a small screwdriver. (included in the box) Turn until the correct pH value.

- Repeat with powder Calibrate 4.00 (included in the box)

- Please Calibrate every 1-3 months (depending on frequency of use) for accuracy of measurement.    

 

How to use the pH meter

- Remove the black cover.

- There may be white crystals on the lid of the machine. Can be washed off with plain water.

- Turn on the device by sliding the on-off button on the top.

- Dip the pH meter into the liquid you want to measure.

- Slowly stir the solution until the displayed pH is stagnant, it should be left for at least 15-30 seconds to ensure a stable pH is obtained.

- After using it should be turned off wash with plain water leave the machine Keep the probe on the bottom until dry. so close the lid

- Do not immerse the probe deeper than 1 cm if immersed too deep. Water can enter the machine and lose it.

 

note should be cleaned with distilled water after using the machine Soak the probe in distilled water for 3-5 minutes, then gently dry the device. (Do not wipe the glass sensor head) and close the lid and store away from heat or sunlight.

 

The company sells pH meters, 4 types of pH paper.

1. High accuracy, lab grade pH meter, waterproof, 1 year warranty.

2. Temporary pH meter, 7 day warranty.

3. High Resolution Benchtop pH Meter (0.01) 1 Year Warranty

4. pH test paper (litmus) 4 colored dots

5. pH test paper (litmus) (1-14, 5m long)

Be the first to review this product :-)

Please login to write a review.
Recommend Lab-Service
Lab Service Price
Digital pH meter (temporary use)

Digital pH meter (temporary use)

Product warranty 7 days

Digital pH Meter Resolution 0.1 pH measurement range 0.0-14.0

The machine is red or yellow, can not choose depending on the stock of the product.

 

*Please calibrate the unit before first use, one set of calibration comes with the machine, please see how to calibrate below*

 

Range : 0.0 - 14.0 pH

Resolution : 0.1 pH

Accuracy : +/- 0.1pH

Operation Temp. : 0 C - 50 C (32 F-122F)

Calibration: 1 point

Power Supply: 1.5V x 4

Battery Life : Approximately 600-800 hours

Size: 148mm x 28 x 15 mm

Weight : 60g

Made from: China

 

 

How to Calibrate the Machine (Please do it before the first use. for accurate measurements)

- Prepare 250ml of distilled water with a temperature of approx. 25 degrees or close

- Pour the Calibrate pH 6.86 powder (included in the box) into the water, stir until completely dissolved.

- In a pH meter dipped in the prepared solution. and check the resulting pH

- If the pH does not match 6.9, use a small screwdriver. (included in the box) Turn until the correct pH value.

- Repeat with powder Calibrate 4.00 (included in the box)

- Please Calibrate every 1-3 months (depending on frequency of use) for accuracy of measurement.    

 

How to use the pH meter

- Remove the black cover.

- There may be white crystals on the lid of the machine. Can be washed off with plain water.

- Turn on the device by sliding the on-off button on the top.

- Dip the pH meter into the liquid you want to measure.

- Slowly stir the solution until the displayed pH is stagnant, it should be left for at least 15-30 seconds to ensure a stable pH is obtained.

- After using it should be turned off wash with plain water leave the machine Keep the probe on the bottom until dry. so close the lid

- Do not immerse the probe deeper than 1 cm if immersed too deep. Water can enter the machine and lose it.

 

note should be cleaned with distilled water after using the machine Soak the probe in distilled water for 3-5 minutes, then gently dry the device. (Do not wipe the glass sensor head) and close the lid and store away from heat or sunlight.

 

The company sells pH meters, 4 types of pH paper.

1. High accuracy, lab grade pH meter, waterproof, 1 year warranty.

2. Temporary pH meter, 7 day warranty.

3. High Resolution Benchtop pH Meter (0.01) 1 Year Warranty

4. pH test paper (litmus) 4 colored dots

5. pH test paper (litmus) (1-14, 5m long)

Mechanism -
Appearance -
Longevity -
Strength -
Storage -
Shelf Life -
Allergen(s) -
Dosage (Range) -
Dosage (Per Day) -
Mix Method -
Heat Resistance -
Stable in pH range -
Solubility -
Product Types -
INCI -

Cart

No products

Subtotal: ฿0.00
฿0.00 Total :