Electrode for Digital pH meter, laboratory, desktop, precision, 2 positions

  • Product Code: 4324

Electrode for benchtop pH meter, resolution 2

฿1,290.00
The above price is special price for customer who purchased the machine from us before. If you do not have purchase record, there is an additional charge of, 200 Baht.
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -
  • -

Electrode for benchtop pH meter, resolution 2

 

(This product is only sold to customers who bought a pH meter from the company.)

 

PH can be measured in the 0-14 pH range or better.

Measurement resolution pH 0.01 pH

Measure the potential difference in the range of ± 1,800 mV.

Resolution of measurement of potential difference 1 mV

Reliability ± 0.01pH ± 1bit / 3h

 

Used with Benchtop pH meter only

 

Cleaning Procedures If the electrode becomes sluggish, or has been determined to be bad, clean the electrode by following the directions below.


General


Soak in 0.1M HCl or 0.1M HNO3 for half an hour.Drain and refill the Electrode Filling Solution.Soak the electrode in Filling or Storage Solution for 1 hour.


Inorganic


Soak in 0.1M tetrasodium EDTA solution 15 minutes.Drain and refill the Electrode Filling Solution.Soak the electrode in Filling or Storage Solution for 1 hour.


Protein


Soak in 1% pepsin in 0.1M HCl for 15 minutes.Drain and refill the Electrode Filling Solution.Soak the electrode in Filling or Storage Solution for 1 hour.


Grease and Oil


Rinse with mild detergent or methanol solution.Drain and refill the Electrode Filling Solution.Soak the electrode in Filling or Storage Solution for 1 hour.

Be the first to review this product :-)

Please login to write a review.
Recommend Lab-Service
Lab Service Price
Electrode for Digital pH meter, laboratory, desktop, precision, 2 positions

Electrode for benchtop pH meter, resolution 2

Electrode for benchtop pH meter, resolution 2

 

(This product is only sold to customers who bought a pH meter from the company.)

 

PH can be measured in the 0-14 pH range or better.

Measurement resolution pH 0.01 pH

Measure the potential difference in the range of ± 1,800 mV.

Resolution of measurement of potential difference 1 mV

Reliability ± 0.01pH ± 1bit / 3h

 

Used with Benchtop pH meter only

 

Cleaning Procedures If the electrode becomes sluggish, or has been determined to be bad, clean the electrode by following the directions below.


General


Soak in 0.1M HCl or 0.1M HNO3 for half an hour.Drain and refill the Electrode Filling Solution.Soak the electrode in Filling or Storage Solution for 1 hour.


Inorganic


Soak in 0.1M tetrasodium EDTA solution 15 minutes.Drain and refill the Electrode Filling Solution.Soak the electrode in Filling or Storage Solution for 1 hour.


Protein


Soak in 1% pepsin in 0.1M HCl for 15 minutes.Drain and refill the Electrode Filling Solution.Soak the electrode in Filling or Storage Solution for 1 hour.


Grease and Oil


Rinse with mild detergent or methanol solution.Drain and refill the Electrode Filling Solution.Soak the electrode in Filling or Storage Solution for 1 hour.

Mechanism -