UV-VIS Ferulic Acid Content Measurement

  • Product Code: 32761

UV-VIS Ferulic Acid Content Measurement

฿2,990.00
ขั้นตอนการให้บริการ
ขั้นตอน ขั้นตอน ผลลัพธ์ที่คาดหวัง
1

50...

1000µg/ml concentration of standard solution.

2

The...

Appropriate concentrations of Ferulic Acid solution within the linearity range

3

The...

The value of maximum absorbance and maximum wavelength.

4

The...

Appropriate concentration of the tested sample within the linearity range

5

The...

The value of Ferulic acid content in the sample .

You will receive a report for the Concentration of Ferulic acid(ug/ml) fields when we provide this service

UV-VIS Ferulic Acid Content Measurement

UV-VIS Ferulic Acid Content Measurement

To determine the assay of ferulic acid using UV-Vis (Ultraviolet-Visible) spectrophotometry, measuring the absorbance of ferulic acid solutions at a specific wavelength. Ferulic acid is a natural phenolic compound found in various plants and is known for its antioxidant and anti-inflammatory properties. Here's a general protocol for conducting a ferulic acid assay:

Materials and Reagents:

Ferulic acid standard sample
Suitable solvent (e.g., ethanol or methanol)
UV-Vis spectrophotometer
Quartz cuvettes
Pipettes and volumetric flasks
Deionized or distilled water
Stirring rod
Weighing balance
UV-Vis software for data collection and analysis
Procedure:

Sample Preparation:
a. Weigh an appropriate amount of ferulic acid standard sample accurately. The exact amount will depend on the expected concentration and the solvent used. Create a standard curve to determine the concentration.

b. Dissolve the ferulic acid standard sample in the selected solvent (e.g., ethanol or methanol) to make a stock solution. Ensure the sample is fully dissolved by stirring.

c. Dilute the stock solution to create a series of standard solutions with different known concentrations. For example, make solutions with concentrations of 10, 20, 30, 40, and 50 µg/mL.

UV-Vis Spectrophotometer Setup:
a. Turn on the UV-Vis spectrophotometer and allow it to warm up for the recommended time.

b. Set the wavelength range to the appropriate value, typically in the UV-Vis range, such as 200-400 nm.

c. Ensure the cuvettes and instrument are clean and free of any particles that may interfere with the measurement.

Blank Correction:
a. Prepare a blank solution using the same solvent used for the standard samples. The blank solution will serve as a reference to account for any absorbance due to the solvent.

b. Place the blank solution in a cuvette and insert it into the spectrophotometer. Set the spectrophotometer to zero absorbance using the blank solution.

Measurement:
a. Take one of the standard solutions and place it in a cuvette.

b. Insert the cuvette into the UV-Vis spectrophotometer.

c. Record the absorbance at the specific wavelength for ferulic acid. The characteristic absorption wavelength for ferulic acid is often around 320-330 nm.

d. Repeat steps a-c for each of the standard solutions.

Data Analysis:
a. Create a standard curve by plotting the known concentrations of the standard solutions against their respective absorbances.

b. Using the standard curve, determine the concentration of ferulic acid in sample solution by measuring its absorbance and interpolating on the curve.

Mechanism -
Appearance -
Longevity -
Strength -
Storage -
Shelf Life -
Allergen(s) -
Dosage (Range) -
Dosage (Per Day) -
Mix Method -
Heat Resistance -
Stable in pH range -
Solubility -
Product Types -
INCI -
Service Steps
Step Procedure Expected Result
1

50...

1000µg/ml concentration of standard solution.

2

The...

Appropriate concentrations of Ferulic Acid solution within the linearity range

3

The...

The value of maximum absorbance and maximum wavelength.

4

The...

Appropriate concentration of the tested sample within the linearity range

5

The...

The value of Ferulic acid content in the sample .