Solid-β-Glucosidase(S-β-GC) Activity Assay Kit

enzyme labeling method

Reagent Code: #67045

blur_circular Chemical Specifications

inventory_2 Storage & Handling
Storage 2-8℃, avoid light

description Product Description

The Solid-β-Glucosidase (S-β-GC) Activity Assay Kit is widely used in research and industrial applications to measure the enzymatic activity of β-glucosidase. This enzyme plays a critical role in breaking down glycosidic bonds in cellulose, making it essential in biofuel production, where it aids in converting cellulose into fermentable sugars. In the food and beverage industry, the kit is employed to monitor β-glucosidase activity during wine and juice production, as the enzyme enhances flavor by releasing aromatic compounds from glycosides. Additionally, it is utilized in environmental studies to assess the enzyme's role in soil health and organic matter decomposition. The kit is also valuable in pharmaceutical research for studying enzyme inhibitors and their potential therapeutic applications. Its simplicity and accuracy make it a preferred tool for quantifying β-glucosidase activity in various biological and industrial samples.

format_list_bulleted Product Specification

Test Parameter Specification
Performance test PASS

Available Sizes & Pricing

Size Availability Unit Price Quantity
100T/EA
10-20 days ฿15,120.00

menu_book Usage Manual

Usage instructions Show / hide

Soil β-Glucosidase (S-β-GC) Activity Assay Kit - Microplate Method

Product Code

67045

Product Introduction

Soil β-glucosidase (S-β-GC) catalyzes the hydrolysis of glycosidic bonds between aryl or hydrocarbon groups and glycosyl groups to produce glucose. It is an important component of the cellulolytic enzyme system and plays important physiological roles in soil microbial carbohydrate metabolism.

S-β-GC catalyzes p-nitrophenyl-β-D-glucopyranoside to produce p-nitrophenol, which has characteristic absorbance at 400 nm.

Package Contents

SizeItem CodeComponentQuantity
100T67045.1Reagent I1 bottle
100T67045.2Reagent II1 bottle
100T67045.3Reagent III1 bottle
100T67045.mInstruction Manual1 copy

Toluene must be prepared separately.

Quality Standards and Safety Information

Raw Material or Packaging NameQuality StandardMain Toxicity
Reagent I----
Reagent II----
Reagent III----

Transportation and Storage

TransportationTransport with ice packs.
StorageStore Reagent I at -20°C. Store the remaining components at 2-8°C, protected from light.
Shelf Life180 days.

Instructions

1. Sample Processing

Air-dry fresh soil samples naturally, or oven-dry at 37°C. Pass the dried samples through a 30-50 mesh sieve.

2. Assay Procedure

  1. Preheat the microplate reader for at least 30 min and set the wavelength to 400 nm.
  2. Before use, add 10 mL double-distilled water to Reagent I. Store any unused portion at -20°C.
  3. Add samples and reagents according to the table below. Set one control tube for each measurement tube.
Component or StepAssay TubeControl Tube
Air-dried soil sample (g)0.020.02
Toluene (μL)1010
Mixing stepShake and mix well at room temperature for 15 minShake and mix well at 90°C for 15 min
Reagent I (μL)130-
Distilled water (μL)-130
Reagent II (μL)160160

Mix well, incubate in a 37°C water bath for 1 h, then immediately boil in a boiling water bath for 5 min. Cap tightly to prevent water loss. Cool under running water.

Centrifuge at 10000g and 25°C for 10 min. Collect the supernatant and add the following reagents to a 96-well plate.

ComponentAssay TubeControl Tube
Supernatant (μL)7070
Reagent III (μL)130130

Mix thoroughly and let stand at room temperature for 2 min. Measure the absorbance at 400 nm as A, then calculate ΔA.

ΔA = Ameasurement- Acontrol

3. S-β-GC Activity Calculation

The regression equation determined under standard conditions is:

y = 0.0016x - 0.0027

In this equation, x is the standard concentration (μmol/L), and y is the absorbance value.

Unit definition: The production of 1 μmol p-nitrophenol per day by 1 g soil sample is defined as one enzyme activity unit.

S-β-GC activity (μmol/d/g) = (ΔA + 0.0027) ÷ 0.0016 × Vtotal reaction÷ W ÷ T = 225 × (ΔA + 0.0027)

  • T: reaction time, 1 h = 1/24 d
  • Vtotal reaction: total volume of the reaction system, 3 × 10-4L
  • W: sample mass, 0.02 g

Precautions

  1. This 100T kit can test 48 samples.
Solid-β-Glucosidase(S-β-GC) Activity Assay Kit
No image available
The Solid-β-Glucosidase (S-β-GC) Activity Assay Kit is widely used in research and industrial applications to measure the enzymatic activity of β-glucosidase. This enzyme plays a critical role in breaking down glycosidic bonds in cellulose, making it essential in biofuel production, where it aids in converting cellulose into fermentable sugars. In the food and beverage industry, the kit is employed to monitor β-glucosidase activity during wine and juice production, as the enzyme enhances flavor by releasing aromatic compounds from glycosides. Additionally, it is utilized in environmental studies to assess the enzyme's role in soil health and organic matter decomposition. The kit is also valuable in pharmaceutical research for studying enzyme inhibitors and their potential therapeutic applications. Its simplicity and accuracy make it a preferred tool for quantifying β-glucosidase activity in various biological and industrial samples.
Mechanism -
Appearance -
Longevity -
Strength -
Long-term storage -
Shelf Life -
Allergen(s) -
Dosage (Range) -
Dosage (Per Day) -
Mix Method -
Heat Resistance -
Stable in pH range -
Solubility -
Product Types -
INCI -

Purchase History for

Loading purchase history...